Skip to content

Elektron Analog Rytm MKI firmware

Elektron active Device launched 2014
Get alerts for new Analog Rytm MKI firmware
Free · one message per release

Latest firmware

1.74
released 1 Oct 2026
Download firmware from elektron.se · needs Elektron Transfer

What's new in 1.74

OS 1.74 adds features for the Analog Rytm MKII only: nothing changes on the MKI. The MKII additions are routing the audio from the Main outputs through Outbox 8, and [FUNC] + [UP/DOWN] navigation between channels in the Outbox 8 channel configuration menus.

Last checked 26 Oct 2026

Release notes on elektron.se ↗

What you get with a free account

  • An alert the day a new Analog Rytm MKI firmware ships, by email, Telegram or push
  • Your whole rig in one place, with the version each device is on
  • Used and new Reverb prices for your gear
  • A public rig page to share, if you want one

We check Elektron's official download page for the Elektron Analog Rytm MKI every day. One message per release. No spam, no newsletter.

Sign in, it’s free →

How to update the Elektron Analog Rytm MKI

Update via USB using Elektron Transfer app (free download from elektron.se). Connect device via USB, open Transfer, drag and drop the .syx OS file onto the Transfer DROP page. The update transfers and installs automatically.

What you need

Elektron Transfer — the software Elektron uses to load firmware onto the Elektron Analog Rytm MKI. Download links below.

Just for reference. For complete and up-to-date instructions, always refer to the manufacturer's official firmware page.

Drivers & software for the Elektron Analog Rytm MKI

The Elektron Analog Rytm MKI is updated with Elektron Transfer, published by Elektron.

Download Elektron Transfer from Elektronopens in a new tab — elektron.se

Sign in to see Reverb prices →

Elektron Analog Rytm MKI firmware update history

8 releases since Apr 2021, roughly one every 9 months.

Changelogs summarised from the manufacturer's release notes.

Version 1.74 — 1 Oct 2026

Release notes for this version are listed above.

Release notesopens in a new tab — elektron.se

Version 1.73 — 9 Sep 2026

Bug fixes: Some devices could become unresponsive when accessing certain samples. A file system check has been added to detect potential problems. If the file system check reports a problem, back up your samples and projects, then reformat the +Drive samples. MIDI messages were sometimes not sent if the device tempo was set to very low BPMs.

Version 1.72 — 30 Jan 2025

Improvements: In the SETTINGS > CONTROLS > SEQUENCER CONFIG menu, there is now a new setting, SAMPLE POS RES, that lets you set if the STA and END parameters should be high or low resolution. [MKI] Setting the high resolution TUN, STA, and END parameters could be difficult. Now, it moves slower, and FUNC-snap is implemented for non-decimal values. Visually, decimal values are now displayed with a dot. When slowly moving such a parameter, there is also a visual indication on the decimal position. The key shortcut to access the PAGE PLAYBACK mode is changed for MKI. It is changed to: In GRID RECORDING mode, press [PAGE] + [NO]. This shortcut is also available on MKII and is added to the previously implemented shortcut of holding down [PAGE] in PLAYBACK mode. Bug fixes: Incorrect tags and machine type could sometimes be displayed when navigating and copying sounds to the Sound Pool. It was not possible to remove a sample lock by pressing DATA ENTRY KNOB D on the SMPL page. [MKI] It was difficult to set ACCENT values due to jittery encoder behavior. When importing projects created in OS prior to 1.70, velocity, aftertouch, performance macro, and scene modulation of TUNE were sometimes not converted correctly. When importing a project that previously was exported from another device, it could under some circumstances, load the wrong samples. Reloading a Sound, Kit, Pattern, or Track could sometimes erroneously also activate the MUTE mode.

Version 1.71 — 16 Oct 2024

Improvements: Randomizing the parameters for the Euclidean sequencer parameter page now bases the randomness range on track length and does not randomize the LEN parameter. The key shortcut to access the PAGE PLAYBACK mode is changed for [MKI]. It is changed to: In GRID RECORDING mode, hold down [PAGE] for two seconds. This shortcut is now also available on [MKII] and is added to the previously implemented shortcut of holding down [PAGE] in PLAYBACK mode. Added support for Overbridge 2.13. Bug fixes: An active GRID RECORDING mode was disabled if the PAD SCALE menu was opened. It was also not possible to enable GRID RECORDING mode again while the PAD SCALE menu was open. The LED BRIGHTNESS screen setting always reverted to MAX after the device was awakened from the screen saver. Parameters on the TRIG PARAMETERS page could sometimes end up on the wrong track if they were recorded using LIVE RECORDING. It was not possible to reload a Sound when in MUTE mode. It was not possible to reload a track when in CHROMATIC mode. Reloading an SRC parameter page could result in reloading errors for specific parameters. The HH LAB DECAY parameter did not have INF as max value name. Calibration could, in some circumstances, fail when a previous calibration result was supposed to be used.

Version 1.70 — 22 Nov 2023

Improvements: Added five new machines: SY CHIP, SY RAW, BD ACOUSTIC, SD ACOUSTIC, and HH LAB. Added an Euclidean mode for the sequencer. You can now save a Sound from a specific trig on the sequencer, complete with its sound- and parameter locks applied. Added the possibility to set a specific number of sequencer steps as record length in the sampler, resulting in loops with the exact length. Added pad scales and fold functionality for when playing the PADS in CHROMATIC mode. Implemented functionality that makes it possible to loop selected pattern pages. Added the square waveform as a parameter value for the WAV parameter in the BD SHARP machine. The BT CLASSIC machine now has a new PITCH ENVELOPE parameter. Added two new PULSE WIDTH parameters for the CB CLASSIC and CB METALLIC machines. Added slew functionality to the RND waveform for the LFOs. When RND is selected for the WAV parameter, the SPH parameter now sets the amount of slew. It is now possible to see which PARAMETER PAGES contain parameters with parameter locks. When pressing and holding specific trig in STEP RECORDING mode, the [PARAMETER] keys that contain parameters with locks light up. Improved oscillator tuning by adding new calibration functionality. Implemented the possibility of generating a random name from the naming screen when naming a Sound or a pattern. The NOTE parameter on the TRIG page now shows the note value and the number of semitones in the screen UI. Improved the naming of the DUAL VCO, IMPULSE, and NOISE GEN machines by adding machine type group naming. The new names are SY DUAL VCO, UT IMPULSE, and UT NOISE. The sample STA and END parameters are now high resolution. It is also now possible to snap to integers for the STA and END parameters. This, together with now showing true integrers in the display, makes it easier to find the exact start and end points in samples, especially in longer samples such as sample chains. [...]

Version 1.61E — 1 Feb 2022

Version 1.61B — 2 Jun 2021

Samples could sometimes become corrupted when transferring them to the Elektron device from an M1 Mac using Transfer. Bug fixes: The USB Class Compliant audio from the computer to the Elektron device could sometimes be silenced. Modulating multiple parameters over MIDI CC or Overbridge could sometimes cause the UI to stop responding. SysEx dumps could become corrupted when sent to certain computer software.

Version 1.61 — 7 Apr 2021

Improvements: Added Overbridge support for macOS Big Sur. Improved the response of the TRACK LEVEL encoder. Bug fixes: Stopping the sequencer did not send a note off message over MIDI on channels that were set to send MIDI notes. Some unused factory content patterns were not properly cleaned and empty. The error message “Missing Cal:Pads” could sometimes be erroneously displayed even though the calibration was not lost. SysEx dumps could become corrupted when sent to certain computer software.

Tracked in 9 rigs on FW//RADAR.

Elektron Analog Rytm MKI firmware FAQ

What is the latest firmware for the Elektron Analog Rytm MKI?

The latest firmware for the Elektron Analog Rytm MKI is version 1.74, released on 1 Oct 2026. FW//RADAR last checked Elektron's official page on 26 Oct 2026.

How do I update the Elektron Analog Rytm MKI?

Update via USB using Elektron Transfer app (free download from elektron.se). Connect device via USB, open Transfer, drag and drop the .syx OS file onto the Transfer DROP page. Full instructions on Elektron's official firmware page.

What software do I need to update the Elektron Analog Rytm MKI?

You need Elektron Transfer, available from elektron.se.

Where can I download Elektron Analog Rytm MKI firmware and drivers?

Directly from Elektron's official firmware page — FW//RADAR links to the source and never hosts firmware files. Official firmware page →

Where can I find the Elektron Analog Rytm MKI manual?

The official Elektron user manual is a PDF hosted on elektron.se. Elektron Analog Rytm MKI user manual (PDF) →

View on Reverb →